Front view of FineTest Burn-In Monitoring Software
Burn-In Monitoring for High Volume Production
Install or Remove a UUT without disrupting the other UUTs
Independent slot monitoring enables different types of UUTs
to be monitored side by side, in the same software, and at the same time
Monitors any combination of the following:
Input Voltage, Output Voltage, Digital Hi/Lo
Status Bits from the UUT through RS-232, RS-485, or i2c
Controls Power Cycling and Thermal Chamber Temperature
In case of Facility Power Outage:
Automatic Software Recovery to pre-fault state
FineSoft on LabWindows CVI platform
The Station Display Panel shows all of the Slots in that Station,
and also displays which Station # and Slot # is currently being monitored
Each Slot shows:
SN -------> Serial Number
P/F ------> Pass or Fail Status (UUT is passing until a failure has occurred)
L. Mon. --> Last time this UUT was Monitored
BI T. ----> Time this UUT has been in Burn-In,or COMPLETED when max time reached
M. BI. ---> Maximum Burn-In Time for this UUT
TRUE -----> Digital Logic "TRUE" is Hi or Lo
(When monitoring Output Voltage, the voltage is shown)
(When monitoring Status Bits, the Bit value is shown)
Print entire Station Status on Paper by selecting PRINT STATUS
View a specific Station Display Panel on the screen by selecting a STATION #
View the next Station Display Panel on the screen by selecting NEXT PANEL!
View the previous Station Display Panel on the screen with PREVIOUS PANEL!
View the Station currently being monitored on the screen with CURRENT PANEL!
Click on INSTALL! to install a new UUT
To install a UUT:
1. Enter the Serial Number
2. Enter the Burn-In Time
3. Select Power Fail Line "True" is Hi/Lo
4. Select the Station #
5. Select the Slot #
Click on REMOVE! to remove a UUT
To remove a UUT:
1. Select the Station #
2. Select the Slot #
You can also print the data of the UUT being removed on the printer